  • Cryo-cooled double crystal monochromator
  • Kirkpatrick-Baez Mirrors (vertical and horizontal focusing)
  • Micro-focusing mirrors (later stage)

DCM - Double Crystal Monochromator

Key Parameters

energy range (keV) 20.0 - 80.0
crystal type Si(111)

crystal dimensions (mm3)

1st crystal (length x width x height)

2nd crystal (length x width x height)

 

172 x 50 x 70

170 x 20 x 50

beam offset distance (mm) 20.0
distance from source (m) 25.6
cooling liquid nitrogen
on axis power loading before filter (kW/mrad2) at 300mA 23.1

Large Kirkpatrick-Baez mirror system

VFM - vertical focussing mirror, HFM - horizontal focussing mirror

The mirrors act for vertical and horizontal focusing and for rejection of high photon energies. They operate in white and monochromatic beam. The different coatings of the HFM provide a set of cut-off energies at constant reflection angle.

Key parameters

mirror length (mm) 1350
active optic length (mm) 1150
slope error (µrad) 1.0
roughness (Å) active area  <3

coating

VFM

HFM: 3 stripes

 

20mm Pt

13 mm Ni, 13 mm Pt, 14 mm Si

distance from source (m)

VFM

HFM

 

29.7

39.9

Small Kirkpatrick-Baez mirror system

Purpose of the secondary, micro-focusing mirrors is to provide a focal spot size of the order of 10 µm (FWHM) in monochromatic beam.

Key parameters

mirror length (mm) 300
active optic area (length x width in mm) 280 x 20
slope error (µrad)  
roughness (Å) active area  

coating

 Pt

distance from source (m)