Diamond Home Page
  • Diamond Home Page
  • About Us
  • For Users
  • Industry
  • Public
  • Science
  • Instruments
  • Careers
  • More
Search

On this website

About Diamond

  • About Diamond
  • About Synchrotron
  • News and Features
  • Events
  • Contact Us
  • FAQ

For Users

  • Apply for beamtime
  • User guide
  • Diamond Users Commitee
  • FAQ

Industry

  • Techniques Available
  • Industry Research
  • Industry Case Studies
  • News
  • Meet the Industry Team

Science

  • Research
  • Computing
  • The Machine
  • Publications
  • Research Expertise
  • Membrane Protein Laboratory
  • Additional Facilities

Instruments

  • All the Instruments
  • Macromolecular Crystallography
  • Soft Condensed Matter
  • Imaging and Microscopy
  • Biological Cryo-Imaging
  • Magnetic Materials
  • Structures and Surfaces
  • Crystallography
  • Spectroscopy

Careers

  • Vacancies
  • Info for applicants
  • Company Benefits
  • Apprenticeships
  • PhD Studentships
  • Work Placement

Public

  • News
  • How Diamond Works
  • Multimedia
  • Features
  • Visits Us
  • For School

Procurement

  • Non-OJEU Tender Notices
  • OJEU PINs
  • OJEU Tender Notices
  • Registration Form

Software & Tools

  • Publications Database
  • iSpyB
  • User Administration System

Main Content

Imaging and Microscopy
Sub-navigation
  • Imaging and Microscopy
  • I08
  • I08-1 (J08)
  • I12
  • DIAD
  • I13
  • I14
  • ePSIC

In This Section

Sub Navigation
  • Coherence Branchline (I13-1)
  • Diamond Manchester Imaging Branchline (I13-2)
    • The Diamond Manchester Collaboration
    • Data Gallery
    • Science Highlights
    • Publications
    • Facilities and Equipment
    • Custom Sample Environments
    • Data beamline
    • Photo Gallery
    • Apply for Beamtime
    • Preparing for Beamtime
  • I13 Publications
  • Staff

Instruments by Science Group

Macromolecular
Crystallography
Soft Condensed
Matter
Imaging and
Microscopy
Biological
Cryo-Imaging
Magnetic
Materials
Structures and
Surfaces
Crystallography
Spectroscopy

I13 Contact

Coherence Branchline (I13-1):
+44 (0) 1235 778827

Diamond Manchester Imaging Branchline (I13-2):
+44 (0) 1235 778831
 

Principal Beamline Scientist: 
Christoph Rau

Tel: +44 (0) 1235 778796
E-mail: christoph.rau@diamond.ac.uk

More

Science Group Leader

Paul Quinn

Email: paul.quinn@diamond.ac.uk
Tel: +44 (0)1235 778583

I13 X-ray Imaging and Coherence

Status: Operational

Energy: Imaging branch: 8 - 30 keV; Coherence branch: 6 - 20 keV

Imaging PCI: Phase Contrast Imaging Tomography Ptychography Bragg CDI CDI: Coherent Diffraction Imaging
  1. Instruments
  2. Imaging and Microscopy
  3. I13
  4. Diamond Manchester Imaging Branchline (I13-2)
  5. Facilities and Equipment

Facilities and Equipment

  • Imaging branch detectors
  • Support facilities

 

pco.4000

(High image quality)

 

 

  • Scintillator-coupled detector
  • 4008 x 2672 pixels
  • Pixel size: 9 µm x 9 µm
  • Dynamic range: 5,455:1
  • Maximum frame rate at full resolution: 5 Hz
  • Exposure time: 5 µs - 49 days
  • Low noise
Available

pco.edge 5.5

(High image quality)

 

 

  • Scintillator-coupled detector
  • 2560 x 2160 pixels
  • Pixel size: 6.5 µm x 6.5 µm
  • Dynamic range: 27,000:1
  • Maximum frame rate at full resolution: 100 Hz
  • Exposure time: 500 µs - 2 s
  • Very low noise
Available

pco.dimax S

(High speed)

 

 

  • Scintillator-coupled detector
  • 2016 x 2016 pixels
  • Pixel size: 11 µm x 11 µm
  • Dynamic range: 1,600:1
  • Maximum frame rate at full resolution: 1,279 Hz
  • Exposure time: 1.5 µs - 40 ms
Available



 
The Imaging branch operates in two imaging modes:

Micro-imaging

Images are recorded with resolutions up to circa 1µm and a choice of magnifications:

Detector

Objective 

lens

Total

magnification*

 

Effective pixel size (µm)

Field of view (mm)

pco.4000

 

1.25x

 

2x

 

4x

 

10x

2.5x

 

4x

 

8x

 

20x

3.6

 

2.25

 

1.125

 

0.45

14 x 9.6

 

9.0 x 6.0

 

4.5 x 3.0

 

1.8 x 1.2

pco.edge 5.5

 

1.25x

 

2x

 

4x

 

10x

2.5x

 

4x

 

8x

 

20x

2.6

 

1.625

 

0.8125

 

0.325

6.7 x 5.6

 

4.2 x 3.5

 

2.1 x 1.8

 

0.83 x 0.70

pco. dimax S

 

2x

 

5x

 

10x

4x

 

10x

 

20x

2.75

 

1.1

 

0.55

5.5 x 5.5

 

2.2 x 2.2

 

1.1 x 1.1

*Note that the setup provides 2x magnification in addition to that provided by the objective lens.

Nano-imaging

An X-ray microscope is used to provide a resolution of approximately 50nm and a field of view of roughly 50µm. The microscope itself is functional and currently being optimised to improve resolution, available photon energies and exposure times.

 

Chemistry laboratory for sample preparation
  • Optical light microscopes (Zeiss Stemi 2000, Zeiss Observer)
  • Refrigerator
  • Oven
  • Fume cupboards
  • Ultrasonic bath
  • Glove box
  • Centrifuge (Eppendorf 5810)
  • Precision saw (Struers Accutom-5)
  • Grinding and polishing machine (Struers LaboPol-5)
Mechanical workshop  
Computing facilities I13 has powerful Linux computers, access to Diamond's cluster and the full suite of Avizo packages for visualising and analysing tomograms.

 

  • Contact Us
  • About Diamond Light Source
  • Careers
  • Procurement
  • Legal notices & Cookie policy
  • Supply Chain Transparency

Diamond Light Source

Diamond Light Source is the UK's national synchrotron science facility, located at the Harwell Science and Innovation Campus in Oxfordshire.

Copyright © 2022 Diamond Light Source

 

Diamond Light Source Ltd
Diamond House
Harwell Science & Innovation Campus
Didcot
Oxfordshire
OX11 0DE

See on Google Maps

Diamond Light Source® and the Diamond logo are registered trademarks of Diamond Light Source Ltd

Registered in England and Wales at Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom. Company number: 4375679. VAT number: 287 461 957. Economic Operators Registration and Identification (EORI) number: GB287461957003.

feedback