Beamlines | I11 - Facility and Equipment availability

Last updated: 9 January 2013

The energy of the beamline is normally set at 15 keV (λ ~ 0.826 Å) for all experiments

With the standard beamstop in position the lowest accessible 2Θ angle is ~ 3 degrees (d ~ 15 Å at 15 keV).

If users would like to operate at different energies, or require access to lower 2Θ angles, please inform your local contact(s) well in advance of the beamtime.

Endstation

Equipment or component
Availability
Comments
Diffractometer (3 circles)
Available
 
High resolution mode: Multi-analysing crystals (MAC): x5 MAC-arms with 45 MAC channels.
Typical collection time per powder pattern: 30 - 60 minutes.
MAC1
Available
Designed 2Θ coverage: 0 - 30°
MAC2
Available
Designed 2Θ coverage: 30 - 60°
MAC3
Available
Designed 2Θ coverage: 60 - 90°
MAC4
Available
Designed 2Θ coverage: 90 - 120°
MAC5
Available
Designed 2Θ coverage: 120 - 150°
Large sample table
(max. load: 500 kg)
Available
 
Small sample table
(max load: 5 kg)
Available
 
Capillary spinner
Available
 
Flat-plate spinner
Available
 
Time-resolved mode:
PSD (Mythen2)
Typical collection time per powder pattern: ms - minutes.
Available
Angular coverage: 2Θ=90°

Sample environments and stages

Robotic arm & carousel
(max. 200 capillary samples)
Available
Cryostream Plus (80 – 500 K)
Available
Hotair blower (RT – 1000 °C)
Available
Capillary furnace
(RT-1500 °C)
Available
PheniX cryostat (11 – 295 K)*
Available
Flat-plate furnace, MRI
(295 -1700 K)
Available
DSC (Linkam)
Available
5K Cryostat (5 – 295 K)**
Available
Humidity chamber
Available
Low Pressure Capillary Gas Cell (mbar – 1.5 bar)  Available
High Pressure Capillary Gas Cell (mbar – 100 bar)  Available

* Please allow at least three hours to change samples.

**Allow one shift of beamtime to allow for set-up and cool-down. Maximum sample turnover one per day.

Support Lab

Basic chemistry lab.
Available
With basic equipment and common solvents
Kit for loading capillary and flat-plate samples
Available
Pestle, mortar, tweezers, spatulas, etc.
Fume cupboard
Available
 
De-ionised water
Available
 
Ultra-sonic baths
Available
 
Small balances (mg – g)
Available
 
Fridge & Freezer
Available
 
Glove Box Available by prior arrangement If the use of a glove box is required please contact beamline staff in advance of your experiment with further details so that this may be arranged.

 

Silicon pattern (SRM 640c): collection time = 30 mins, l=0.826982 ÅSilicon pattern (SRM 640c): collection time = 30 mins, λ=0.826982 Å

I11 Beamline Manual

The draft beamline manual for I11 is available here.