Beamline specifications
Restrictions apply. Please contact beamline staff well in advance to discuss feasibility.
Operational modes
| Feature | Availability | Comments |
| Monochromatic focused (4-20 keV) | Available | |
| Monochromatic unfocused (4-25 keV) | Available | |
| White beam | Available | |
| Monochromatic, focused or unfocused (2–4 keV)
| Limited availability | Very low flux as beam exits through a Be window. |
| Beam size: Focused < 200 μm x 200μm | Available | In microfocused mode, the beam size is energy / focal length dependent. |
Optics
| Equipment | Availability | Comments |
| Double Crystal Monochromator | Available | |
| Toroidal mirror (1:1 focusing) | Available | Focal distance of the mirror can be adjusted to keep the beam in-focus at any position along the 12m length of the experimental hutch. |
| DCM bandpass: ~1.8 x10-4 | Available | Divergence limited bandpass. No collimating mirror – the DCM is the first optical element. |
| Double Multilayer Monochromator - for higher-order suppression and for high-flux modes | Available | |
| Micro / Nano-focusing optics | Available |
Experimental Hutch
| Equipment or detector | Availability | Comments |
| 5-circle Huber Diffractometer with Chi cradle | Available | - Angular range of some axes is restricted by mounts and beamline delivery systems. Available angular ranges are given here. -2Theta (δ) range can be changed/adjusted, if needed. |
| XYZ sample stage on Diffractometer X = ±25 mm Y = ±25 mm Z = ±12.5 mm Load capacity ≤20 kg | Available | |
| Versatile Optics Table Optics/sample station Diagnostics station X = ±25 mm Y = ±25 mm Theta = ±135° Phi = ±10° X Piezo=300 mm Y Piezo=300 mm Load capacity ≤5 kg Detector station X = ±50 mm Y = ±50 mm Load capacity ≤ 20 kg Relative motions (along beam direction and transverse) possible between the three stations. | Available | |
| Large area X-ray diffraction detector : Photonic Science X-ray Image Star 9000, 135mm dia, 3056 x 3056 pixels, 31 mm optical pixel size | Available | |
| X-ray Eye: Photonic Science X-ray MiniFDI, 11mm dia, 1392 x 1040 pixels, 6.5μm optical pixel size | Available | |
| VORTEX 90EX X-ray spectroscopy detector: Active area = 50mm2 Energy resolution ~ 150 eV @5.9 keV | Available | |
| High Resolution X-ray Microscope: - PCO CCD camera 4008 x 2672 pixels, 14bit dynamic range - Objectives :1.25X to 40X - Several optimized scintillators - Theoretical spatial resolution limit <0.5 μm | Available | |
| Uniblitz fast shutter (6mm opening aperture, to be used with focused or slitted beams) | Limited Availability | |
| APD Ultrafast X-ray detector Active Area : 10mm x 10mm Max count rate: 100 MHz | Available | |
| Other Detectors: PIPS diodes, scintillation counter and ionization chambers | Available | |
| Various general-purpose viewing cameras | Available | |
Support labs
| Equipment | Availability | Comments |
| Zeiss Stereo Optical Microscope | Available | |
| Laminar Flow table | Available | |
| Fume cupboard, small balance (mg – g), ultrasonic bath, etc | Available | |
| Dark room for photographic film development | Available |
For any further information, please contact a member of the beamline staff.